Summary for Test 2017-07-25-8-1
Test performed: CONCLP 3-16Project Information
Project Identifiers | Project ID: 212572 DEA: 030G9404 EFIS: 0317000204 |
---|---|
DIST-CO-RTE-PM | 03-SAC,YOL/SAC-5,50-2.4/L0.7 |
Award Date | 06/21/2017 |
Closeout Date | 04/16/2021 |
Work Description | Remove MLS and 1" polyester concrete overlay on Pioneer Bridge in Sacramento, CA. |
Location Description | Sacramento, CA |
QA Service Level | 1 (Verified on 07/12/2017) |
Sample Information
Sample Taken Date | 07/25/2017 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/25/2017 |
Sample type | Quality Control | A brief description of the sample | 1 gallon can |
The quantity of what the sample constitutes | 2 tankers | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Nunes |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Kwik bond and Reichhold | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Polyester | Mfg. Lot Number(s) | 1065791 |
---|---|---|---|
Batch number | 1065791 | Mix number | 1065791 |
Test Details
DIME Sample ID: 2017-07-25-8
DIME Test ID: 2017-07-25-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-10-06
Test Results
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 10/06/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 126 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.077
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 58.7 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3135 psi
Styrene ASTM D 2369 40% to 50 %: 46 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 619 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.4 grams
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/6/2017 ✔