Summary for Test 2017-07-25-8-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 212572
DEA: 030G9404
EFIS: 0317000204
DIST-CO-RTE-PM03-SAC,YOL/SAC-5,50-2.4/L0.7
Award Date06/21/2017
Closeout Date04/16/2021
Work DescriptionRemove MLS and 1" polyester concrete overlay on Pioneer Bridge in Sacramento, CA.
Location DescriptionSacramento, CA
QA Service Level1 (Verified on 07/12/2017)

Sample Information

Sample Taken Date07/25/2017 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/25/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1065791
Batch number1065791 Mix number1065791

Test Details

DIME Sample ID: 2017-07-25-8
DIME Test ID: 2017-07-25-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-10-06

Test Results


Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 10/06/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 126 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.077
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 58.7 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3135 psi
Styrene ASTM D 2369 40% to 50 %: 46 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 619 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.4 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/6/2017