Summary for Test 2013-12-03-8002992-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 3995 DEA: 072332A4 EFIS: 0700000390 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-R46.3/R50.0 |
Award Date | 02/27/2012 |
Closeout Date | 06/02/2015 |
Work Description | WIDEN ROADWAY AND BRIDGES WITH PCC AND CONSTRUCT RETAINING WALLS. |
Location Description | LOS ANGELES COUNTY IN AND NEAR SANTA CLARITA FROM 0.3 MILE SOUTH OF WELDON CANYON OVERCROSSING TO 0.4 MILE SOUTH OF PICO CANYON ROAD/LYONS AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 04/23/2012) |
Sample Information
Sample Taken Date | 12/03/2013 | Sample Unique Key | 8002992 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2013 |
Sample type | Acceptance | A brief description of the sample | Structure Backfill Material |
The quantity of what the sample constitutes | 1bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | RW 2578 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | RW 2578 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
The plant number | Not set | A detailed description of where the material sample was collected | RW 2578 |
Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2013-12-03-8002992
DIME Test ID: 2013-12-03-8002992-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2015-02-20
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 12/11/2013
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 99 %
Cumulative percent passing the 1 in. sieve: 98 %
Cumulative percent passing the 3/4 in. sieve: 97 %
Cumulative percent passing the 1/2 in. sieve: 94 %
Cumulative percent passing the 3/8 in. sieve: 91 %
Cumulative percent passing the #4 sieve: 84 %
Cumulative percent passing the #8 sieve: 76 %
Cumulative percent passing the #16 sieve: 68 %
Cumulative percent passing the #30 sieve: 55 %
Cumulative percent passing the #50 sieve: 39 %
Cumulative percent passing the #100 sieve: 28 %
Cumulative percent passing the #200 sieve: 19 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔