Summary for Test 2017-09-20-10-4
Test performed: ASTM A615-15Project Information
Project Identifiers | Project ID: 212393 DEA: 044K4704 EFIS: 0417000313 |
---|---|
DIST-CO-RTE-PM | 04-ALA-13-4.4, 4.40 |
Award Date | 02/17/2017 |
Closeout Date | 12/17/2019 |
Work Description | This is a slide repair project on ALA-13-4.4 (Southbound RTE 13/ Westbound Rte 580 Off-Ramp). Construct Solider Pile Wall & regrade slope. |
Location Description | In Alameda County, In Oakland, at Calaveras Avenue |
QA Service Level | 1 (Verified on 04/24/2017) |
Sample Information
Sample Taken Date | 09/20/2017 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/25/2017 |
Sample type | Quality Assurance | A brief description of the sample | 10 Soil Nails with nut |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Con-Tech systems | Transportation Laboratory (TL) Number | C741437 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B908317 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | #10 |
Nut Specification for Threaded Bar | A615 | System Manufacturer | Con Tech |
Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
Coating Standards | Uncoated | Bar Heat Number(s) | A170356, A170365 |
Nut Heat Number(s) | 8290416 | Bar Lot Number | Unknown |
Nut Lot Number | 3947 | Coupler Heat Number(s) | Unknown |
Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2017-09-20-10
DIME Test ID: 2017-09-20-10-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-10-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 09/26/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | #10 Bar Heat #A170365, Nut Heat #3947 | B908317 | 1.27 | 117077 | 85300 | 5.4 | A615 Bar & Nut, Nut Strip Out Bar Did Not Break | Fred |
General comments (publicly viewable) (Max 1000 characters): A615 Bar & Nut, Nut Strip Out Bar Did Not Break
Test Graph
Source: Partner Data Point FileTest was verified on 9/27/2017 ✔