Summary for Test 2025-02-04-12-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 215220 DEA: 07210624 EFIS: 0719000068 |
---|---|
DIST-CO-RTE-PM | 07-LA,SBD-71-1.8/R4.7&R0.0/R0.2 |
Award Date | 02/05/2021 |
Closeout Date | Not set |
Work Description | PLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP. |
Location Description | IN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE. |
QA Service Level | 1 (Verified on 03/24/2021) |
Sample Information
Sample Taken Date | 02/04/2025 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/04/2025 |
Sample type | Quality Assurance | A brief description of the sample | Aggregate Base |
The quantity of what the sample constitutes | 2000 SY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Arroyo |
Title of sampler | Materials Tester | Telephone number of sampler | 7605743880 |
Laboratory sample identification | 25-0483 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Nb Route 71 Median |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Aggregate Base | The fabricator/manufacturer designation for the sample | Compactions Testing |
The plant number | A detailed description of where the material sample was collected | Jobsite | |
Where the material sample would have been placed if not sampled | Jobsite | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-02-04-12
DIME Test ID: 2025-02-04-12-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-02-06
Test Results
Method Type:: Direct Read
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rigoberto Arroyo
Date of test: 02/04/2025
Gage No.: 80494
Test No.: 2
Nuclear By: Rigoberto Arroyo
Non-Bias Plan No.: 1
Depth: 8"
Material No.: Aggregate Base
Material Type: Aggregate Base
Impact By: Rigoberto Arroyo
Standard Count Density: 2695 g/cc
Count or Density 1: 1298 g/cc
Count or Density 2: 1291 g/cc
Count or Density 3: 1340 g/cc
Count or Density 4: 1265 g/cc
Count or Density 5: 1369 g/cc
Standard Count Moisture: 721 g/cc
Moisture Count 1: 126 g/cc
Moisture Count 2: 122 g/cc
Moisture Count 3: 141 g/cc
Moisture Count 4: 131 g/cc
Moisture Count 5: 126 g/cc
Sum of Count or Density: 6563 g/cc
Average of Count or Density: 1312.6 g/cc
Sum of Moisture Count: 646 g/cc
Average of Moisture Count: 129.2 g/cc
Calculated Percent Relative Compaction: 97.3 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2025 ✔