Summary for Test 2024-12-04-63-3
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 12/04/2024 | Sample Unique Key | 63 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/16/2024 |
Sample type | Verification | A brief description of the sample | Tank |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Donald | Last name of sampler or witnessed by | Weeks |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 120424-36 | Linked DIME Sample ID | 2024-12-04-50 |
The fabricator/manufacturer/facility name | Fontana CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | 10:00am | HMA Supplier | |
Certified Asphalt Supplier | Advantage Sealing Systems - Fontana CA | Multigrade | Yes |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-12-04-63
DIME Test ID: 2024-12-04-63-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-01-30
Test Results
Phase: PAV residue
Input Type: Measured
Tester's full name: Alexis Vargas-Bastida
Date of test: 01/10/2025
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 64.385 kPa
Phase Angle (δ) (for the 10 cycles): 41.6 degree
Complex Modulus (G*) (for the 10 measurements): 6,406.173 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 4253 kPa
General comments (publicly viewable) (Max 1000 characters): PAV
Test was verified on 1/30/2025 ✔