Summary for Test 2024-09-30-35-1
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 995059 DEA: 081G6404 EFIS: 0816000046 |
---|---|
DIST-CO-RTE-PM | 08-SBD-395-R4.0/49.0 |
Award Date | 10/25/2023 |
Closeout Date | Not set |
Work Description | REPLACE ASPHALT CONCRETE SURFACING, COLD PLANE AC PVMT AND RHMA. |
Location Description | SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM ROUTE 15/395 SEPARATION TO 3.1 MILES NORTH OF ROUTE 58/395 SEPARATION |
QA Service Level | 1 (Verified on 08/15/2023) |
Sample Information
Sample Taken Date | 09/30/2024 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2024 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | joseph | Last name of sampler or witnessed by | valle |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 1069-30T | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Sully Miller | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | CT590F25 |
---|---|---|---|
The truck number from where the sample was collected | 242 | The batch plant ticket number from where the sample was collected | 2083089 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | JOB | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-09-30-35
DIME Test ID: 2024-09-30-35-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-12-11
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 10/28/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 51720 lb
Maximum load on cylinder 2: 49280 lb
Maximum load on cylinder 3: 50320 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4080.0 psi
Compressive strength of cylinder 2: 3900.0 psi
Compressive strength of cylinder 3: 3980 psi
Compressive strength (to nearest 10 psi): 3990 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/11/2024 ✔