Summary for Test 2017-08-17-8-1
Test performed: ASTM A934-13Project Information
Project Identifiers | Project ID: 209187 DEA: 04235624 EFIS: 0400000678 COOP: 042583 |
---|---|
DIST-CO-RTE-PM | 04-SCL,SM-101-52.0/52.6,0.0/0.6 |
Award Date | 04/28/2015 |
Closeout Date | 01/08/2020 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND EAST PALO ALTO FROM OREGON EXPRESSWAY OVERCROSSING TO 0.3 MILE SOUTH OF UNIVERSITY AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 12/11/2013) |
Sample Information
Sample Taken Date | 08/17/2017 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/01/2017 |
Sample type | Retest | A brief description of the sample | Purple Epoxy Coated HRC 555 End Anchors |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Clement | Last name of sampler or witnessed by | Chan |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rebar Fletcher Coating | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4067827 | Head Manufacturer Lot Number(s) | 1, 2 |
Rebar Size | #8 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
Head Manufacturer | CMC HRC | Head Fabricator | CMC Rebar |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2017-08-17-8
DIME Test ID: 2017-08-17-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2017-09-12
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 09/01/2017
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 12 mils
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 14.79 mils
First Bar Side 2 mean value: 9.35 mils
Second Bar Side 1 mean value: 11.99 mils
Second Bar Side 2 mean value: 17.07 mils
First Bar Mean: 12.07 mils
Second Bar Mean: 14.53 mils
Total mean value: 13.3 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/5/2017 ✔