Summary for Test 2024-10-23-51-9
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993529 DEA: 11430514 EFIS: 1119000008 |
---|---|
DIST-CO-RTE-PM | 11-SD-15-R31.3/R37.1 |
Award Date | 05/27/2022 |
Closeout Date | Not set |
Work Description | CRCP, FIBER OPTIC CABLE, AND HMA. |
Location Description | SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 02/07/2022) |
Sample Information
Sample Taken Date | 10/23/2024 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA RPSU |
The quantity of what the sample constitutes | 3 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | 6193804522 | |
Laboratory sample identification | 6672-RPSU | Linked DIME Sample ID | 2024-10-23-50 |
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0098 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | 53417105 MM |
Test Details
DIME Sample ID: 2024-10-23-51
DIME Test ID: 2024-10-23-51-9
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-11-06
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 10/31/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 1547.3 grams
Mass of container filled with the sample and water for Sample 1: 8406.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.512
Theoretical maximum density at 25°C (77°F): 156.4 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): RAP
Test was verified on 11/6/2024 ✔