Summary for Test 2024-10-15-25-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 1000649 DEA: 061H3404 EFIS: 0625000042 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-23.49 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | BRIDGE REPAIR FOR BR #46 0192 |
Location Description | Tulare County along NB SR 99 at Avenue 184 OC, Bridge #46 0192. |
QA Service Level | 1 (Verified on 09/26/2024) |
Sample Information
Sample Taken Date | 10/15/2024 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/16/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMA Type A |
The quantity of what the sample constitutes | 10 Boxes 2 Bags 4 Cans | From where was the sample collected | Source |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
Title of sampler | QC | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Porterville Rock and Recycle | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | 23J018 |
Test Details
DIME Sample ID: 2024-10-15-25
DIME Test ID: 2024-10-15-25-2
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-10-16
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Jason Ruiz
Date of test: 10/16/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7318.7 grams
Mass of oven-dry sample in air for Sample 1: 2559.7 grams
Mass of container filled with the sample and water for Sample 1: 8932.3 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.706
Theoretical maximum density at 25°C (77°F): 2698.2 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/16/2024 ✔