Summary for Test 2024-09-13-68-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
---|---|
DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
Award Date | 07/13/2023 |
Closeout Date | Not set |
Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 09/13/2024 | Sample Unique Key | 68 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 RHMA-G |
The quantity of what the sample constitutes | 0-750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Magana | Last name of sampler or witnessed by | Luis |
Title of sampler | Telephone number of sampler | 2092250104 | |
Laboratory sample identification | HW-090924-ACSE1 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials-Pleasanton | Transportation Laboratory (TL) Number | C690435 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 9 | HMA Mix Number | D04 JMF 24 035 |
Test Details
DIME Sample ID: 2024-09-13-68
DIME Test ID: 2024-09-13-68-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-14
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Conception
Date of test: 09/18/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2157.6 g
Mass Loss: 181.8 g
Correction Factor (Percent by mass of HMA Specimen): 1.01 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.28 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2024 ✔