Summary for Test 2017-08-10-2-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 211797 DEA: 080G8424 EFIS: 0814000184 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R107.3 |
Award Date | 12/29/2016 |
Closeout Date | 06/23/2021 |
Work Description | UPGRADE EXISTING SAFETY ROADSIDE REST AREAS (SRRA) |
Location Description | SAN BERNARDINO COUNTY ABOUT 30 MILES EAST OF BARSTOW AT C.V. KANE SAFETY ROADSIDE REST AREA |
QA Service Level | 1 (Verified on 02/08/2017) |
Sample Information
Sample Taken Date | 08/10/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2017 |
Sample type | Verification | A brief description of the sample | 3/4 inch assorted anchor bolts |
The quantity of what the sample constitutes | Various | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 562-229-9279 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | California Steel Products | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-076-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 145517 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 Gr 36 |
Bolt Length(s) | 7-7/8", 9", 9-1/2", 10" | Nut Specification | N/A |
Washer Specification | N/A | Finish | hot-dip galvanized |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 145517 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | None |
Test Details
DIME Sample ID: 2017-08-10-2
DIME Test ID: 2017-08-10-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-08-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/22/2017
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | F1554 Gr 36 Bolt 10 Deg Wedge | 0.334 | 23605 | 105 | 70674 | 45412 | 15168 | F1554 Gr 36 Bolt |
General comments (publicly viewable) (Max 1000 characters): F1554 Gr 36 Bolt
Test Graph
Source: Partner Data Point FileTest was verified on 8/23/2017 ✔