Summary for Test 2024-09-24-97-5
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 993387 DEA: 07323404 EFIS: 0716000064 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-R59.5/R67.9 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | PLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING |
QA Service Level | 1 (Verified on 12/06/2021) |
Sample Information
Sample Taken Date | 09/24/2024 | Sample Unique Key | 97 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/26/2024 |
Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | HUTARDO |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan-Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-09-24-97
DIME Test ID: 2024-09-24-97-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-10-09
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 10/08/2024
Time of test: 6:25 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 47.5 %
Viscosity reading #1 (A) : 0.237 Pa-s
Viscosity reading #2 (B) : 0.236 Pa-s
Viscosity reading #3 (C): 0.238 Pa-s
Average viscosity: 0.237 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/9/2024 ✔