Summary for Test 2017-08-11-8-1
Test performed: ASTM C42-13Project Information
Project Identifiers | Project ID: 210862 DEA: 031F4004 EFIS: 0300020420 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-35.1/38.3 |
Award Date | 03/10/2016 |
Closeout Date | 06/19/2020 |
Work Description | WIDEN EASTBOUND ROADWAY |
Location Description | WIDEN EASTBOUND ROADWAY |
QA Service Level | 1 (Verified on 10/20/2015) |
Sample Information
Sample Taken Date | 08/11/2017 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/14/2017 |
Sample type | Verification | A brief description of the sample | cores |
The quantity of what the sample constitutes | 3.70 cores | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Haas |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | unk | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Concrete Core | Detail description | pl17176 |
---|---|---|---|
Structure names | pl1717 | Type of material | concrete |
Test Details
DIME Sample ID: 2017-08-11-8
DIME Test ID: 2017-08-11-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C42-13: Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete
Test Release Date: 2017-08-18
Test Results
Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 08/15/2017
Length of Core: 6.14 in
Diameter of Core: 3.65 in
Type of Fracture: 1
Age of Specimen: 50 days
L/D Ratio: 1.7
Compressive Strength: 51685 psi
Correction Factor: 0.97
Corrected Strength: 4790 psi
Calculated Density: 0 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/18/2017 ✔