Summary for Test 2024-09-26-73-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 1000062 DEA: 061F8204 EFIS: 0623000100 |
---|---|
DIST-CO-RTE-PM | 06-FRE-168-39.6/45.7 |
Award Date | 05/10/2024 |
Closeout Date | Not set |
Work Description | COLD PLANE AC PVMT, HMA (TYPE A), PAINT TRAFFIC STRIPES. |
Location Description | FRESNO COUNTY IN AND NEAR SHAVER LAKE FROM 0.2 MILE WEST OF CRESSMAN ROAD TO WARBLER ROAD |
QA Service Level | 1 (Verified on 01/29/2024) |
Sample Information
Sample Taken Date | 09/26/2024 | Sample Unique Key | 73 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/04/2024 |
Sample type | Acceptance | A brief description of the sample | PG 64-28 |
The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Source |
First name of sampler or witnessed by | G | Last name of sampler or witnessed by | Lu |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Albina Chowchilla | Transportation Laboratory (TL) Number | 955976 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 4 | Tank number | |
Time of sample | HMA Supplier | Ashlan Vulcan Materials, fresno | |
Certified Asphalt Supplier | Albina Asphalt - Chowchilla CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-09-26-73
DIME Test ID: 2024-09-26-73-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-10-09
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 10/07/2024
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.242 kPa
Phase Angle (δ) (for the 10 cycles): 77.0 degree
Complex Modulus (G*) (for the 10 measurements): 2.005 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.06 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 10/9/2024 ✔