Summary for Test 2024-09-17-94-1
Test performed: AASHTO T59-22Project Information
Project Identifiers | Project ID: 55556 DEA: OCR EFIS: OCR |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Oregon Corp. Research. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/17/2024 | Sample Unique Key | 94 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2024 |
Sample type | Acceptance | A brief description of the sample | CRS-2P |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Oregon Cooperative Test Group | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphaltic Emulsion | Emulsion Grade | CRS-2 |
---|---|---|---|
Lot Number | Not set | Sub Lot | Not set |
Test Details
DIME Sample ID: 2024-09-17-94
DIME Test ID: 2024-09-17-94-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2024-10-04
Test Results
Is Correction factor required?: No
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 10/04/2024
What temperature wil you be testing Saybolt Furol Viscosity?: 50 C
Efflux time (ET) for test sample: 224.5 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 225 sec
Test efflux temperature: 50 F
General comments (publicly viewable) (Max 1000 characters): @ 50C
Test was verified on 10/4/2024 ✔