Summary for Test 2024-09-25-7-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000255
DEA: 081N7504
EFIS: 0823000045
DIST-CO-RTE-PM08-SBD-138,189-21.4/R37.8,0.0/5.6
Award Date06/12/2024
Closeout DateNot set
Work DescriptionSLURRY SEAL, TWO-COMPONENT PAINT TRAFFIC STRIPE, REPLACE AC SURFACING.
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 138 FROM BOLINGBROKE ROAD TO ROUTE 18 AND ON ROUTE 189 FROM ROUTE 18 TO ROUTE 173
QA Service Level1 (Verified on 05/15/2024)

Sample Information

Sample Taken Date09/25/2024 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/25/2024
Sample typeAcceptance A brief description of the sample3/4" HMA A SP R15 NO LAS
The quantity of what the sample constitutes2 BOXES OF HMA, 1 QT PG64-10, 1 BAG RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byMaryanna Last name of sampler or witnessed byLandaverde
Title of sampler Telephone number of sampler
Laboratory sample identification0497A-24 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105793

Test Details

DIME Sample ID: 2024-09-25-7
DIME Test ID: 2024-09-25-7-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-01

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Carlos Lievanos
Date of test: 09/27/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2,123.1 g
Mass Loss: 102.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.44 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/1/2024