Summary for Test 2017-08-10-7-1

Test performed: ASTM A775-07b-re14

Project Information

Project IdentifiersProject ID: 212461
DEA: 033H2904
DIST-CO-RTE-PM03-NEV,NEV/PLA-80-R2.5/69.23
Award Date04/25/2017
Closeout Date09/30/2021
Work DescriptionReplace damaged culvert and repair sinkhole
Location DescriptionNot set
QA Service Level1 (Verified on 08/10/2017)

Sample Information

Sample Taken Date08/10/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/14/2017
Sample typeQuality Assurance A brief description of the sampleepoxy coated dowel basket and epoxy coated rebar basket
The quantity of what the sample constitutes2 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byLeach
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) NumberC925914
Inspector Lot Number from the Transportation Laboratory (TL) Form33810617 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat NumberSE17102274 rebar SE17102286
Dowel Epoxy Batch NumberNA Dowel Coating SpecificationASTM A775
Dowel Size1.5 in Dowel Coating ColorGreen
Dowel ManufacturerNucor Dowel CoaterDayton Superior
Release Number1347114-1 1347114-2 Quality Assurance CodeUnknown
Rebar Size (#)

Test Details

DIME Sample ID: 2017-08-10-7
DIME Test ID: 2017-08-10-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2017-08-23

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/16/2017
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 16 mils
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 11.66 mils
First Bar Side 2 mean value: 8.561 mils
Second Bar Side 1 mean value: 11.9 mils
Second Bar Side 2 mean value: 12.12 mils
First Bar Mean: 10.11 mils
Second Bar Mean: 12.01 mils
Total mean value: 11.06 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/16/2017