Summary for Test 2017-08-10-6-1

Test performed: ASTM A884-14

Project Information

Project IdentifiersProject ID: 211390
DEA: 060L3404
EFIS: 0600000301
DIST-CO-RTE-PM06-FRE-168-T30.1/T30.4
Award Date06/20/2016
Closeout Date03/12/2020
Work DescriptionCONSTRUCT ROUNDABOUT AT INTERSECTION.
Location DescriptionFRESNO COUNTY AT PRATHER FROM 0.1 MILE WEST TO 0.1 MILE EAST OF AUBERRY ROAD
QA Service Level1 (Verified on 10/04/2016)

Sample Information

Sample Taken Date08/10/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/14/2017
Sample typeQuality Assurance A brief description of the sampleEpoxy Coated Dowel Basket
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byEd Last name of sampler or witnessed byLeach
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) NumberC925913
Inspector Lot Number from the Transportation Laboratory (TL) Form53810517 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat NumberSE17102274
Dowel Epoxy Batch Number524968 Dowel Coating SpecificationASTM A775
Dowel Size1.5 in Dowel Coating ColorGreen
Dowel ManufacturerNucor Dowel CoaterBradley Coatings Group
Release Number1346894-1 Quality Assurance CodeUnknown
Rebar Size (#)

Test Details

DIME Sample ID: 2017-08-10-6
DIME Test ID: 2017-08-10-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Test Release Date: 2017-08-23

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/16/2017
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 40 mils
First Bar Side 1 mean value: 12.29 mils
First Bar Side 2 mean value: 12.57 mils
Second Bar Side 1 mean value: 11.17 mils
Second Bar Side 2 mean value: 12.32 mils
First Bar Mean: 12.43 mils
Second Bar Mean: 11.75 mils
Total mean value: 12.09 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/16/2017