Summary for Test 2024-07-24-120-4

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date07/24/2024 Sample Unique Key120
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2024
Sample typeQuality Control A brief description of the sampleaggregate
The quantity of what the sample constitutes63CY From where was the sample collectedJob Site
First name of sampler or witnessed byEdgar Last name of sampler or witnessed byCortes
Title of samplerField Technician Telephone number of sampler
Laboratory sample identificationL242115 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNorthgate Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Northgate Ready mix
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedplant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberB753BF15 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-07-24-120
DIME Test ID: 2024-07-24-120-4
Testing Lab: Pavement Engineers
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-09-26

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Roland Ocansey
Date of test: 07/29/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.3
Sand reading (test 1): 4.7
Clay reading (test 2): 4.5
Sand reading (test 2): 3.9
Clay reading (test 3): 4.7
Sand reading (test 3): 4.1
Sand equivalent (test 1): 89
Sand equivalent (test 2): 87
Sand equivalent (test 3): 88
Sand equivalent before temperature correction: 88
Sand equivalent after temperature correction: 88
General comments (publicly viewable) (Max 1000 characters): concrete sand

Test was verified on 9/26/2024