Summary for Test 2017-07-18-11-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 211931
DEA: 043G6414
EFIS: 0416000348
DIST-CO-RTE-PM04-NAP-29-37.0
Award Date03/17/2017
Closeout Date04/22/2020
Work DescriptionSCOUR REPLACE BRIDGE
Location DescriptionNAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE
QA Service Level1 (Verified on 02/15/2017)

Sample Information

Sample Taken Date07/18/2017 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/24/2017
Sample typeAcceptance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes36 CY From where was the sample collectedJob Site
First name of sampler or witnessed byChris Last name of sampler or witnessed byMoultan
Title of samplerStructures Rep Telephone number of sampler510-714-7031
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShamrock Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameNapa River Bridge Calistoga

Material Information

Material TypeConcrete The concrete mix design number4700
The truck number from where the sample was collected1212 The batch plant ticket number from where the sample was collected718498
Concrete batch plantShamrock Napa The fabricator/manufacturer designation for the sample28 Day Compressive Strength
A detailed description of where the material sample was collectedRevolving Truck Where the material sample would have been placed if not sampledAbut 1 Pile 1
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2017-07-18-11
DIME Test ID: 2017-07-18-11-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-08-15

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 08/15/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 162687 lb
Maximum load on cylinder 2: 159885 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 5773.1 psi
Compressive strength of cylinder 2: 5691.9 psi
Compressive strength (to nearest 10 psi): 5730 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Cylinder Code 1 of 2

Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 8/15/2017