Summary for Test 2024-09-03-60-2
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 994696 DEA: 100Y7704 EFIS: 1015000008 |
---|---|
DIST-CO-RTE-PM | 10-MPA-140-12.0/22.1 |
Award Date | 07/11/2023 |
Closeout Date | Not set |
Work Description | REPLACE AC SURFACING, PLACE HMA AND RHMA, AND BRIDGE REPAIR. |
Location Description | MARIPOSA COUNTY NEAR MARIPOSA FROM 1.3 MILES EAST OF CATHEYS VALLEY PARK TO 0.1 MILE NORTH OF ROUTE 49 |
QA Service Level | 1 (Verified on 05/09/2023) |
Sample Information
Sample Taken Date | 09/03/2024 | Sample Unique Key | 60 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Timothy | Last name of sampler or witnessed by | Trefz |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 24-H-113 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | George Reed - Table Mountain Plant | Transportation Laboratory (TL) Number | 0Y77112 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 12 | HMA Mix Number | 24J3 |
Test Details
DIME Sample ID: 2024-09-03-60
DIME Test ID: 2024-09-03-60-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-09-19
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 09/17/2024
Specific Gravity for Sample 1: 2.453
Theoretical maximum density at 25°C (77°F): 152.6 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/19/2024 ✔