Summary for Test 2024-08-08-115-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
---|---|
DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
Award Date | 07/13/2023 |
Closeout Date | Not set |
Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 08/08/2024 | Sample Unique Key | 115 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/24/2024 |
Sample type | Quality Assurance | A brief description of the sample | 1/2 RHMA-O |
The quantity of what the sample constitutes | 751-1500 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | H | Last name of sampler or witnessed by | Sadie |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | OGFC |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 9 | HMA Mix Number | DO4 OGFC 24 001 |
Test Details
DIME Sample ID: 2024-08-08-115
DIME Test ID: 2024-08-08-115-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-18
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: LEO MENDOZA
Date of test: 08/24/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2,068.0 g
Mass Loss: 175.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.97 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.35 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/18/2024 ✔