Summary for Test 2024-09-06-20-1
Test performed: ASTM C39-18Project Information
Project Identifiers | Project ID: 993253 DEA: 033F0604 EFIS: 0312000052 |
---|---|
DIST-CO-RTE-PM | 03-GLE-162-76.3/78.6 |
Award Date | 02/02/2022 |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
Sample Taken Date | 09/06/2024 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2024 |
Sample type | Quality Assurance | A brief description of the sample | PCC |
The quantity of what the sample constitutes | Frame 6 S&S, Pour 2, Set 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Nicholas | Last name of sampler or witnessed by | McLean |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Mathews Readymix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 07215P15 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 16029285 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | On Job Site at Concrete Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-09-06-20
DIME Test ID: 2024-09-06-20-1
Testing Lab: CT D03 - Chico Field Laboratory
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-09-14
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Brad McKeehan
Date of test: 09/14/2024
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 55340 lb
Maximum load on cylinder 2: 57420 lb
Maximum load on cylinder 3: 58670 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4402.5 psi
Compressive strength of cylinder 2: 4568.0 psi
Compressive strength of cylinder 3: 4667.5 psi
Compressive strength (to nearest 10 psi): 4550 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/14/2024 ✔