Summary for Test 2024-08-23-1-2

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 212720
DEA: 07291404
EFIS: 0712000094
DIST-CO-RTE-PM07-LA-1-55-58
Award Date02/18/2021
Closeout DateNot set
Work DescriptionTRANCAS CREEK BRIDGE REPLACEMENT
Location DescriptionIN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027).
QA Service Level1 (Verified on 04/02/2021)

Sample Information

Sample Taken Date08/23/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/26/2024
Sample typeQuality Assurance A brief description of the sample#9 HRC 150 T-Heads
The quantity of what the sample constitutes16 Headed Bars From where was the sample collectedFabricator
First name of sampler or witnessed byJacob Last name of sampler or witnessed byGarcia
Title of samplerQuality Assurance Inspector Telephone number of sampler3109128014
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC- Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL169-057-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)9002408 Head Manufacturer Lot Number(s)400000945421
Rebar Size#9 Headed Bar Model NameHRC Type 150
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeCircular Rebar ManufacturerCMC Steel Arizona
Head ManufacturerNucor Utah Head FabricatorHRC Fountian Valley
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-04

Test Details

DIME Sample ID: 2024-08-23-1
DIME Test ID: 2024-08-23-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2024-09-03

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 08/30/2024
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1119629496294Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/3/2024