Summary for Test 2017-07-19-7-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/19/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2017 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 77 | From where was the sample collected | Source |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | 10861 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S577317, S0541717, S0588417, S0588517, S0561417, S0567617, S0561517, S0520517, S0548117, S0520917, S0541817, S0588617, S0588117, S0588217, S0541917, S0541217, S0577417, S0514116, S0541517, S0290926 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2017-07-19-7
DIME Test ID: 2017-07-19-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-08-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/03/2017
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0541717 | S334103-2 | 0.217 | 59214 | 55192 | 28.1 | 1.71 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/4/2017 ✔