Summary for Test 2024-08-01-130-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 994966
DEA: 073255U4
EFIS: 0722000129
DIST-CO-RTE-PM07-LA-605-20.2/26
Award Date04/12/2023
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC
Location DescriptionLOS ANGELES COUNTY IN BALDWIN PARK AND IRWINDALE FROM ROUTE 10/605 SEPARATION TO 0.2 MILE NORTH OF ROUTE 210/605 SEPARATION
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date08/01/2024 Sample Unique Key130
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/01/2024
Sample typeQuality Assurance A brief description of the sampleNative Material
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byJareerattana Last name of sampler or witnessed bySirisujarittha
Title of sampler Telephone number of sampler
Laboratory sample identification24-2346 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCTM 231 Test Holes
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-08-01-130
DIME Test ID: 2024-08-01-130-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-08-29

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Jareerattana Sirisujarittha
Date of test: 08/29/2024
Gage No.: no data
Test No.: no data
Nuclear By: no data
Non-Bias Plan No.: no data
Depth: no data
Material No.: no data
Material Type: no data
Impact By: no data
Standard Count Density: 1752 g/cc
Count or Density 1: 1799 g/cc
Count or Density 2: 1916 g/cc
Count or Density 3: 2076 g/cc
Standard Count Moisture: 725 g/cc
Moisture Count 1: 247 g/cc
Moisture Count 2: 257 g/cc
Moisture Count 3: 184 g/cc
Sum of Count or Density: 5791 g/cc
Average of Count or Density: 1930.33 g/cc
Sum of Moisture Count: 688 g/cc
Average of Moisture Count: 229.33 g/cc
Calculated Percent Relative Compaction: 90.8 %
Reported Percent Relative Compaction: 91 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/29/2024