Summary for Test 2024-08-13-66-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214135
DEA: 09213404
EFIS: 0900000030
DIST-CO-RTE-PM09-INY-395-29.9/41.8
Award Date10/22/2021
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location DescriptionINYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
QA Service Level1 (Verified on 05/03/2019)

Sample Information

Sample Taken Date08/13/2024 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/13/2024
Sample typeQuality Assurance A brief description of the sampleHMA76
The quantity of what the sample constitutesUp to 750 tons (250 tons per core) From where was the sample collectedJob Site
First name of sampler or witnessed byColton Last name of sampler or witnessed byCarrington
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFisher Sand and Gravel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number76 HMA Mix Number

Test Details

DIME Sample ID: 2024-08-13-66
DIME Test ID: 2024-08-13-66-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-20

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Jerid Kupelian
Date of test: 08/15/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4274.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6373 g
Mass of HMA Sample prior to ignition: 2098.8 g
Mass Loss: 95.8 g
Mass of aggregate remaining after ignition: 2003 g
Correction Factor (Percent by mass of HMA Specimen): 0.07 %
Moisture Content: 0 %
Temperature Compensation Factor: 0 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.49 %
General comments (publicly viewable) (Max 1000 characters): HMA-76

Test was verified on 8/20/2024