Summary for Test 2024-08-13-83-5
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 994147 DEA: 120R4104 EFIS: 1218000090 |
---|---|
DIST-CO-RTE-PM | 12-ORA-1-17.4/21.5 |
Award Date | 09/27/2022 |
Closeout Date | Not set |
Work Description | COLD PLANE AC AND PLACE RHMA-G. |
Location Description | ORANGE COUNTY IN NEWPORT BEACH FROM JAMBOREE ROAD TO SANTA ANA RIVER BRIDGE |
QA Service Level | 1 (Verified on 06/28/2023) |
Sample Information
Sample Taken Date | 08/13/2024 | Sample Unique Key | 83 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2024 |
Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
First name of sampler or witnessed by | RJ Noble QC | Last name of sampler or witnessed by | RJ Noble QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | R.J.Noble-Orange | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-08-13-83
DIME Test ID: 2024-08-13-83-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-08-20
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Anthony Hernandez
Date of test: 08/20/2024
Time of test: 06:02 HH:MM
Test Temperature: 135 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 87.3 %
Viscosity reading #1 (A) : 0.445 Pa-s
Viscosity reading #2 (B) : 0.446 Pa-s
Viscosity reading #3 (C): 0.454 Pa-s
Average viscosity: 0.448 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/20/2024 ✔