Summary for Test 2024-08-11-4-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994696 DEA: 100Y7704 EFIS: 1015000008 |
---|---|
DIST-CO-RTE-PM | 10-MPA-140-12.0/22.1 |
Award Date | 07/11/2023 |
Closeout Date | Not set |
Work Description | REPLACE AC SURFACING, PLACE HMA AND RHMA, AND BRIDGE REPAIR. |
Location Description | MARIPOSA COUNTY NEAR MARIPOSA FROM 1.3 MILES EAST OF CATHEYS VALLEY PARK TO 0.1 MILE NORTH OF ROUTE 49 |
QA Service Level | 1 (Verified on 05/09/2023) |
Sample Information
Sample Taken Date | 08/11/2024 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 RHMA-G |
The quantity of what the sample constitutes | 2 boxs | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Timothy | Last name of sampler or witnessed by | Trefz |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 24-H-95 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | George Reed - Table Mountain Plant | Transportation Laboratory (TL) Number | 0Y77205 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 2 |
Sublot number | 5 | HMA Mix Number | 24J5 |
Test Details
DIME Sample ID: 2024-08-11-4
DIME Test ID: 2024-08-11-4-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-15
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 08/14/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2005.5 g
Mass Loss: 168.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.33 %
Moisture Content: 0 %
Temperature Compensation Factor: 0 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.07 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/15/2024 ✔