Summary for Test 2017-07-18-19-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 211948 DEA: 073W2204 EFIS: 0716000011 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R0.0/R15.8 |
Award Date | 02/15/2017 |
Closeout Date | 08/28/2019 |
Work Description | REPLACE BRIDGE APPROACH SLABS AND REHABILITATE DECKS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES AND GLENDALE FROM NORTH CONNECTOR OVERCROSSING TO HONOLULU AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 04/20/2017) |
Sample Information
Sample Taken Date | 07/18/2017 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2017 |
Sample type | Quality Assurance | A brief description of the sample | A307A Threaded Rod |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | George | Last name of sampler or witnessed by | Lujan |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Ulmer Industries | Transportation Laboratory (TL) Number | C940652 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L3600917 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 405414 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A307A | |
Bolt Length(s) | 3'-8" | Nut Specification | NA |
Washer Specification | NA | Finish | A153 / F2329 |
Diameter/Size | .750 | Bolt Mfg. Lot Number | 1 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-07-18-19
DIME Test ID: 2017-07-18-19-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-07-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/24/2017
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | A307 A .750\" x 44\" threaded Rod | 0.334 | 25620 | 113 | 76707 | 64613 | 21581 | A307 A Threaded Stud |
General comments (publicly viewable) (Max 1000 characters): A307 A Threaded Stud
Test Graph
Source: Partner Data Point FileTest was verified on 7/24/2017 ✔