Summary for Test 2024-07-24-76-1
Test performed: ASTM A416-18Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/24/2024 | Sample Unique Key | 76 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/31/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 0.5 PT Strand |
| The quantity of what the sample constitutes | 28 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S133077-4, S133077-5, S133081-1, S133081-4 | Number of Coils | |
| Group Number | 11015 | Strand Diameter | .5 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0598224, S0599524 | Mfg. Lot Number(s) | NA |
| Manufacturer(s) | Sumiden |
Test Details
DIME Sample ID: 2024-07-24-76
DIME Test ID: 2024-07-24-76-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2024-08-14
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: AAuvinen
Date of test: 08/08/2024
UTM: 120kip
Temperature: 72 f
Extensometers: E88766
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0598224 | S133077-4 | 0.155 | 43415 | 40068.4 | 28.2 | 2.01 | AAuvinen |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 8/14/2024 ✔