Summary for Test 2024-07-12-79-2
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
| Award Date | 07/13/2023 |
| Closeout Date | Not set |
| Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
| Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
| Sample Taken Date | 07/12/2024 | Sample Unique Key | 79 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2 RHMA-G HMA |
| The quantity of what the sample constitutes | 0 to 750 tons | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Barajas |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 5 |
| Sublot number | 15 | HMA Mix Number | DO4 JMF 22 041 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-07-12-79
DIME Test ID: 2024-07-12-79-2
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-08-01
Test Results
Number of Samples: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Luis Magana
Date of test: 07/17/2024
Specific Gravity for Sample 1: 2.434
Specific Gravity for Sample 2: 2.424
Average Specific Gravity: 2.429
Theoretical maximum density at 25°C (77°F): 2422 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/1/2024 ✔