Summary for Test 2024-05-15-36-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 994773
DEA: 081C7704
EFIS: 0813000017
DIST-CO-RTE-PM08-SBD-15-80.6,R119.1
Award Date06/20/2023
Closeout DateNot set
Work DescriptionCAST-IN-DRILLED-HOLE CONC PILE, FURNISH & INSTALL SIGN STR, AND MGS.
Location DescriptionSAN BERNARDINO COUNTY NEAR BARSTOW AT 1.2 MILES SOUTH OF GHOST TOWN ROAD AND AT 1.4 MILES SOUTH OF BASIN ROAD
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date05/15/2024 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/16/2024
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byFrancisco Last name of sampler or witnessed byRuvalcaba
Title of samplerTET Telephone number of sampler
Laboratory sample identification1066-1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHi Grade Oro Grande Transportation Laboratory (TL) Number1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberHG98537S
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSB I15 4259+82 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-05-15-36
DIME Test ID: 2024-05-15-36-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-07-17

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 06/12/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 64880 lb
Maximum load on cylinder 2: 67570 lb
Maximum load on cylinder 3: 65530 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 5112.7 psi
Compressive strength of cylinder 2: 5350.0 psi
Compressive strength of cylinder 3: 5163.9 psi
Compressive strength (to nearest 10 psi): 5210 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/17/2024