Summary for Test 2024-07-02-69-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 1000114
DEA: 060W8204
EFIS: 0617000304
DIST-CO-RTE-PM06-KIN-41-28.4/R40.1
Award Date05/22/2024
Closeout DateNot set
Work DescriptionCOLD PLANE WITH HOT MIX ASPHALT (TYPE A) AND RHMA-G.
Location DescriptionKINGS COUNTY AT AND NEAR STRATFORD FROM NEVADA AVENUE TO ROUTE 41/198 SEPARATION
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date07/02/2024 Sample Unique Key69
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/12/2024
Sample typeVerification A brief description of the sampleSS-1H Emulsified Asphalt
The quantity of what the sample constitutes1 jar From where was the sample collectedJob Site
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2024-07-02-69
DIME Test ID: 2024-07-02-69-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2024-07-15

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 07/15/2024
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 151.0 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 132.5 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 150.4 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 132.2 g
Beaker 1 Residue: 37.0 %
Beaker 2 Residue: 36.4 %
Percentage of residue: 37 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 7/15/2024