Summary for Test 2017-06-12-6-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 211593
DEA: 034F0904
DIST-CO-RTE-PM03-SAC-5,80-17.2,M8.9
Award Date09/20/2016
Closeout Date08/30/2018
Work DescriptionREHABILITATE BRIDGE DECKS
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO ON ROUTE 5 AT FLORIN ROAD OVERCROSSING AND ON ROUTE 80 AT DEL PASO PARK OVERHEAD
QA Service Level1 (Verified on 10/20/2016)

Sample Information

Sample Taken Date06/12/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/12/2017
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1057685
Batch number1057685 Mix number1057685

Test Details

DIME Sample ID: 2017-06-12-6
DIME Test ID: 2017-06-12-6-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-07-11

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 07/11/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 96.5 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 57 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2716 psi
Styrene ASTM D 2369 40% to 50 %: 45.3 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 689 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.5 grams
General comments (publicly viewable) (Max 1000 characters): accepted bond on coc

Test was verified on 7/11/2017