Summary for Test 2024-07-05-2-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000114
DEA: 060W8204
EFIS: 0617000304
DIST-CO-RTE-PM06-KIN-41-28.4/R40.1
Award Date05/22/2024
Closeout DateNot set
Work DescriptionCOLD PLANE WITH HOT MIX ASPHALT (TYPE A) AND RHMA-G.
Location DescriptionKINGS COUNTY AT AND NEAR STRATFORD FROM NEVADA AVENUE TO ROUTE 41/198 SEPARATION
QA Service Level1 (Verified on 02/26/2024)

Sample Information

Sample Taken Date07/05/2024 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/06/2024
Sample typeAcceptance A brief description of the samplePPC Cylinders
The quantity of what the sample constitutes300 From where was the sample collectedJob Site
First name of sampler or witnessed byMartin Last name of sampler or witnessed byGarcia
Title of samplerStructure Representative Telephone number of sampler5592469430
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameOutback Materials, Fresno Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier45-0014
Structure nameEmpire No. 2 Canal Bridge

Material Information

Material TypeConcrete The concrete mix design number72T1G36
The truck number from where the sample was collected2 The batch plant ticket number from where the sample was collected111
Concrete batch plantOutback Materials The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampledNB Arrival and Departure Approach Slabs
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-07-05-2
DIME Test ID: 2024-07-05-2-3
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-07-12

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 07/12/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 46310 lb
Maximum load on cylinder 2: 46660 lb
Maximum load on cylinder 3: 49170 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3,684.2 psi
Compressive strength of cylinder 2: 3,712.0 psi
Compressive strength of cylinder 3: 3,911.7 psi
Compressive strength (to nearest 10 psi): 3770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/12/2024