Summary for Test 2024-05-23-90-6
Test performed: CTM 389-19Project Information
Project Identifiers | Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243 |
---|---|
DIST-CO-RTE-PM | 11-SD-5-37.4-52.6 |
Award Date | 10/20/2023 |
Closeout Date | Not set |
Work Description | I-5 NCC SEGMENT 4C |
Location Description | I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing |
QA Service Level | 1 (Verified on 11/20/2023) |
Sample Information
Sample Taken Date | 05/23/2024 | Sample Unique Key | 90 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/25/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMA-A |
The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | 6193804522 | |
Laboratory sample identification | 0604-PSU | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan CC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 220817 CC SJR |
Test Details
DIME Sample ID: 2024-05-23-90
DIME Test ID: 2024-05-23-90-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-07-15
Test Results
Specified number of passes at 12.7 mm: 15000
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/03/2024
Test Temperature: 122 F
HMA Production: Lab
Compaction Method: SGC Cylindrical Specimen
Binder High PG Grade: no data
Binder Content TWM: no data
Air Void Content: no data
Aggregate Gradation: no data
Type and Amount of Anti-Stripping Additive: Yes 0.5%
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 2.32 mm
Maximum impression at 5000 passes (right wheel): 1.48 mm
Average impression at 5000 passes (left/right avg): 1.9 mm
Maximum impression at 10000 passes (left wheel): 2.7 mm
Maximum impression at 10000 passes (right wheel): 1.66 mm
Average impression at 10000 passes (left/right avg): 2.18 mm
Maximum impression at 15000 passes (left wheel): 3.02 mm
Maximum impression at 15000 passes (right wheel): 1.85 mm
Average impression at 15000 passes (left/right avg): 2.44 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Complies 2.44 mm < 12.7 mm
Test was verified on 7/15/2024 ✔