Summary for Test 2024-06-04-24-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 995260 DEA: 061G0504 EFIS: 0623000195 |
---|---|
DIST-CO-RTE-PM | 06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0 |
Award Date | 03/29/2023 |
Closeout Date | Not set |
Work Description | Routes 180, 245 Emergency Slip Out Repair |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/20/2023) |
Sample Information
Sample Taken Date | 06/04/2024 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/05/2024 |
Sample type | Verification | A brief description of the sample | PCC cylinders |
The quantity of what the sample constitutes | 55 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Sok | Last name of sampler or witnessed by | Thun |
Title of sampler | ASR | Telephone number of sampler | 559 240 2128 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Outback Materials, Fresno | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 06-1G0504 | |
Structure name | Concrete Barrier Slab |
Material Information
Material Type | Concrete | The concrete mix design number | 72T1X39 |
---|---|---|---|
The truck number from where the sample was collected | 113 | The batch plant ticket number from where the sample was collected | 160996 |
Concrete batch plant | Outback Materials | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | Concrete Barrier Slab at Wall 2 |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-06-04-24
DIME Test ID: 2024-06-04-24-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-07-03
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 07/03/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.03 in
Average diameter of cylinder 2: 4.03 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 82360 lb
Maximum load on cylinder 2: 81950 lb
Maximum load on cylinder 3: 84620 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 29 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.76 in^2
Cross sectional area of cylinder 2: 12.76 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 6,454.5 psi
Compressive strength of cylinder 2: 6,422.4 psi
Compressive strength of cylinder 3: 6,668.2 psi
Compressive strength (to nearest 10 psi): 6520 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/3/2024 ✔