Summary for Test 2024-06-29-5-1
Test performed: ASTM C1064-17Project Information
Project Identifiers | Project ID: 1000310 DEA: 041X5804 EFIS: 0424000402 |
---|---|
DIST-CO-RTE-PM | 04-SON-116-19.9 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Remove 12" AC overlay on the Jones Creek Bridge and Install precast pre-stressed slab girder. |
Location Description | Jones Creek Bridge (Bridge # 20-0094) in Sonoma 116 post mile 19.9 |
QA Service Level | 1 (Verified on 05/14/2024) |
Sample Information
Sample Taken Date | 06/29/2024 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/05/2024 |
Sample type | Quality Assurance | A brief description of the sample | RSC |
The quantity of what the sample constitutes | 2.61 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | Calderon |
Title of sampler | Telephone number of sampler | 9164252912 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Precision Concrete | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Jones Bridge |
Material Information
Material Type | Concrete | The concrete mix design number | 80371TP |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 945 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete from wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-06-29-5
DIME Test ID: 2024-06-29-5-1
Testing Lab: CT SC - 3672 - Santa Rosa
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2024-08-05
Test Results
Input Type: Measured
Tester's full name: Jose Calderon Mares
Date of test: 06/29/2024
Temperature: 83 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/5/2024 ✔