Summary for Test 2024-06-20-114-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 995124 DEA: 060X3004 EFIS: 0618000051 |
---|---|
DIST-CO-RTE-PM | 06-FRE-33-69.4/71.5 |
Award Date | 02/06/2024 |
Closeout Date | Not set |
Work Description | REPLACE ROADWAY PAVEMENT. |
Location Description | FRESNO COUNTY IN AND NEAR FIREBAUGH FROM MORRIS KYLE DRIVE TO LYON AVENUE |
QA Service Level | 1 (Verified on 10/25/2023) |
Sample Information
Sample Taken Date | 06/20/2024 | Sample Unique Key | 114 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/20/2024 |
Sample type | Acceptance | A brief description of the sample | 3/4" Recycled class 2 AB |
The quantity of what the sample constitutes | 0-1000 Tons | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jonathon | Last name of sampler or witnessed by | Chaney |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bay Cities | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Jobsite material |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | STA 197+50 | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-06-20-114
DIME Test ID: 2024-06-20-114-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-06-27
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 06/26/2024
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 98 %
Cumulative percent passing the 1/2 in. sieve: 81 %
Cumulative percent passing the 3/8 in. sieve: 71 %
Cumulative percent passing the #4 sieve: 53 %
Cumulative percent passing the #8 sieve: 42 %
Cumulative percent passing the #16 sieve: 35 %
Cumulative percent passing the #30 sieve: 27 %
Cumulative percent passing the #50 sieve: 16 %
Cumulative percent passing the #100 sieve: 9 %
Cumulative percent passing the #200 sieve: 5.9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/27/2024 ✔