Summary for Test 2024-05-23-90-2
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243 |
---|---|
DIST-CO-RTE-PM | 11-SD-5-37.4-52.6 |
Award Date | 10/20/2023 |
Closeout Date | Not set |
Work Description | I-5 NCC SEGMENT 4C |
Location Description | I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing |
QA Service Level | 1 (Verified on 11/20/2023) |
Sample Information
Sample Taken Date | 05/23/2024 | Sample Unique Key | 90 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/25/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMA-A |
The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | 6193804522 | |
Laboratory sample identification | 0604-PSU | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan CC | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 220817 CC SJR |
Test Details
DIME Sample ID: 2024-05-23-90
DIME Test ID: 2024-05-23-90-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-07-15
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 06/26/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7477.1 grams
Mass of oven-dry sample in air for Sample 1: 2049.7 grams
Mass of container filled with the sample and water for Sample 1: 8714.5 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.523
Theoretical maximum density at 25°C (77°F): 157.0 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Complies Target 2.515
Test was verified on 7/15/2024 ✔