Summary for Test 2024-06-05-1-2

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date06/05/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/20/2024
Sample typeQuality Assurance A brief description of the sampleH.S. Fastener Assembly
The quantity of what the sample constitutes30 From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler5624420352
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCraneVeyor Corp Transportation Laboratory (TL) NumberL140-044-24
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10857400, 100893010, 214482 Nut Mfg. Lot Number(s)425907A
Washer Mfg. Lot Number(s)214482 Bolt SpecificationASTM A325
Bolt Length(s)3 1/2" Nut SpecificationASTM A 563 DH
Washer SpecificationASTM F436 FinishHDG
Diameter/Size1/2" Bolt Mfg. Lot NumberE161N1
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2024-06-05-1
DIME Test ID: 2024-06-05-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-06-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 06/24/2024
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A24497Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 6/28/2024