Summary for Test 2024-05-31-25-5
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/31/2024 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2024 |
Sample type | Verification | A brief description of the sample | JMF 3/4" HMA-A-SP R15, 0.75% LAS |
The quantity of what the sample constitutes | 4 Bags of Coldfeed Agg. 2 Bags of Rap | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jesse/ R | Last name of sampler or witnessed by | Gomez/Balan |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0273A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Belt Cut at Vulcan Materials- Corona | |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-05-31-25
DIME Test ID: 2024-05-31-25-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-07-09
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Larry Diaz
Date of test: 06/14/2024
Clay Level (Test 1): 4.9
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.1
Sand Level (Test 2): 3.8
Clay Level (Test 3): 4.9
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 80
Sand Equivalent (Test 2): 75
Sand Equivalent (Test 3): 78
Sand Equivalent: 78
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/9/2024 ✔