Summary for Test 2024-06-12-7-2

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date06/12/2024 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/12/2024
Sample typeQuality Assurance A brief description of the sample5
The quantity of what the sample constitutes5 From where was the sample collectedJob Site
First name of sampler or witnessed byJD Last name of sampler or witnessed byJD
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number00000
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected00000
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-06-12-7
DIME Test ID: 2024-06-12-7-2
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-07-23

Test Results


Number of specimens: 2
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Outside of the Middle Third of the Span Length by No More Than 5 Percent
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Alexis Corona
Date of test: 06/20/2024
Identification number: 000
Width of specimen: 0.0625 inch
Width of specimen 2: 0.0625 inch
Depth of specimen: 0.0625 inch
Depth of specimen 2: 0.0625 inch
Span length of specimen: 2 inch
Span length of specimen 2: 3 inch
Maximum recording: 2 psi
Maximum recording 2: 4 psi
Average distance from line of fracture to the nearest support: 0.25 inch
Average distance from line of fracture to the nearest support 2: 0.1875 inch
Curing history and apparent moisture condition of the specimen: 8
If specimen was capped, ground or if leather shims were used: 8
Defects in specimen, including numbers of beams discarded during test: 5
Age of specimen: 8 days
Age of specimen in hours: 3 hours
Modulus of rupture: 10 psi
Modulus of rupture 2: 10 psi
Modulus of rupture average: 10 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/23/2024