Summary for Test 2017-06-14-6-7

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 211669
DEA: 022C0904
EFIS: 0200000161
DIST-CO-RTE-PM02-PLU-70-50.6/51.7
Award Date11/16/2016
Closeout Date11/12/2020
Work DescriptionBRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT
Location DescriptionPLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD
QA Service Level1 (Verified on 10/25/2016)

Sample Information

Sample Taken Date06/14/2017 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/20/2017
Sample typeVerification A brief description of the sampleA563-DH HDG Nut
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCT METS QA INSPECTOR Telephone number of sampler(801) 669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-062-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10387930 Nut Mfg. Lot Number(s)15-01-005
Washer Mfg. Lot Number(s) Bolt Specificationn/a
Bolt Length(s)Unknown Nut SpecificationA563-DH
Washer Specificationn/a FinishHDG
Diameter/Size1/2" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-06-14-6
DIME Test ID: 2017-06-14-6-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-07-05

Test Results


Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 06/28/2017
Sample No.: 6C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 15-01-005
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DMC DH
Size: .5 in
Bolt Length: no data
Measurement Average: 5.44 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/28/2017