Summary for Test 2024-05-22-65-3
Test performed: AASHTO T30-19Project Information
Project Identifiers | Project ID: 993432 DEA: 11423804 EFIS: 1116000061 |
---|---|
DIST-CO-RTE-PM | 11-SD-94,125-R9.8/R10.6,12.9/22.3 |
Award Date | 04/27/2022 |
Closeout Date | Not set |
Work Description | CONSTRUCT INDIVIDUAL SLAB, HMA, RHMA, MODIFY LANDSCAPE AND ELECTRICAL. |
Location Description | SAN DIEGO COUNTY ON ROUTE 94 FROM E94/N125 SEPARATION IN LEMON GROVE TO 0.1 MILE EAST OF SPRING STREET UNDERCROSSING IN LA MESA AND ON ROUTE 125 FROM 0.6 MILE SOUTH OF SPRING STREET UNDERCROSSING NEAR LA MESA TO MISSION GORGE ROAD IN SANTEE |
QA Service Level | 1 (Verified on 12/20/2021) |
Sample Information
Sample Taken Date | 05/22/2024 | Sample Unique Key | 65 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2024 |
Sample type | Quality Assurance | A brief description of the sample | HMA-A |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Source |
First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Fuentes |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0708-A | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | 21218080SR MM |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2024-05-22-65
DIME Test ID: 2024-05-22-65-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2024-06-04
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 05/31/2024
Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
---|---|---|---|---|---|---|
1424 grams | ||||||
0.0 grams | 0.0 % | 100 % | ||||
0.0 grams | 0.0 % | 100 % | ||||
0.0 grams | 0.0 % | 100 % | ||||
0.0 grams | 0.0 % | 100 % | ||||
44.0 grams | -0.4 % | 97 % | ||||
236.0 grams | -0.3 % | 83 % | ||||
897.0 grams | -1.9 % | 35 % | ||||
1097.0 grams | -2.2 % | 21 % | ||||
1204.0 grams | -1.9 % | 14 % | ||||
1279.0 grams | -1.5 % | 9 % | ||||
1337.0 grams | -0.6 % | 6 % | ||||
1369.0 grams | 0.1 % | 4 % | ||||
1382.0 grams | 0.6 % | 3.5 % | ||||
1383.0 grams |
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 6/4/2024 ✔