Summary for Test 2017-06-21-9-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/21/2017 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/23/2017 |
Sample type | Quality Assurance | A brief description of the sample | A449 HDG all thread |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Other |
First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Leach |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S3808017 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 24332 | |
Washer Mfg. Lot Number(s) | Bolt Specification | F449 | |
Bolt Length(s) | 12" | Nut Specification | A563 HDG |
Washer Specification | na | Finish | HDG |
Diameter/Size | 0.625 | Bolt Mfg. Lot Number | 304298 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-06-21-9
DIME Test ID: 2017-06-21-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-07-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/26/2017
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | A449 7/8\" x 12\" Althreaded Rod w/ Nut | 0.226 | 31630 | 140 | 139956 | 129575 | 29284 | A449 and Nut Proof |
General comments (publicly viewable) (Max 1000 characters): A449 and Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 6/27/2017 ✔