Summary for Test 2017-06-06-12-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
Project Identifiers | Project ID: 212527 DEA: 101F6801 EFIS: 1017000066 |
---|---|
DIST-CO-RTE-PM | 10-MPA-120-Var |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Repair of five culverts in Mariposa County along Route 120 with concrete liners. |
Location Description | In Mariposa County in and near Buck Meadows at various locations. |
QA Service Level | 1 (Verified on 04/11/2019) |
Sample Information
Sample Taken Date | 06/06/2017 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2017 |
Sample type | Quality Control | A brief description of the sample | Upstream invert of culvert |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ray | Last name of sampler or witnessed by | Chang |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 17SOIL-0176 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C703193D |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | NA |
Where the material sample would have been placed if not sampled | 0 to 1 ft |
Test Details
DIME Sample ID: 2017-06-06-12
DIME Test ID: 2017-06-06-12-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-06-28
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 06/21/2017
Total mass of material in the sample: 2621 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 47 grams
Cumulative mass retained on the 3/4 in. sieve: 11 grams
Cumulative mass retained on the 1/2 in. sieve: 10 grams
Cumulative mass retained on the 3/8 in. sieve: 14 grams
Cumulative mass retained on the #4 sieve: 40 grams
Cumulative mass retained on the #8 sieve: 28 grams
Total sample mass passing the #4 sieve: 1061 grams
Total mass of fine material in the sample: 529 grams
Cumulative mass retained on the pan: 501 grams
Total cumulative mass of coarse aggregate: 122 grams
Total cumulative mass of fine aggregate: 529 grams
Sum of coarse and fine aggregate: 1183 grams
Percentage of coarse material: 10 %
Percentage of fine material: 90 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 96 %
Cumulative percent passing the 3/4 in. sieve: 95 %
Cumulative percent passing the 1/2 in. sieve: 94 %
Cumulative percent passing the 3/8 in. sieve: 93 %
Cumulative percent passing the #4 sieve: 90 %
Cumulative percent passing the #8 sieve: 85 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/21/2017 ✔