Summary for Test 2024-04-16-85-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 995232 DEA: 120U1704 EFIS: 1223000051 |
---|---|
DIST-CO-RTE-PM | 12-ORA-133,261-9.8/12.6,0.0/3.5 |
Award Date | 12/27/2023 |
Closeout Date | 09/20/2024 |
Work Description | COLD PLANE, OVERLAY, AND REFRESH PAVEMENT DELINEATION. |
Location Description | ORANGE COUNTY IN IRVINE ON ROUTE 133 FROM TECHNOLOGY DRIVE UNDERCROSSING TO PORTOLA PARKWAY UNDERCROSSING AND ON ROUTE 261 FROM WALNUT AVENUE OVERCROSSING TO 0.6 MILE NORTH OF PORTOLA PARKWAY OVERCROSSING |
QA Service Level | 1 (Verified on 10/16/2023) |
Sample Information
Sample Taken Date | 04/16/2024 | Sample Unique Key | 85 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2024 |
Sample type | Quality Assurance | A brief description of the sample | 1/2 RHMAG |
The quantity of what the sample constitutes | 1/2 RHMAG | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jimmy | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 24-0413 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | AAA - CORONA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2024-04-16-85
DIME Test ID: 2024-04-16-85-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-07-01
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 05/14/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7309 grams
Mass of oven-dry sample in air for Sample 1: 1553.9 grams
Mass of container filled with the sample and water for Sample 1: 8230.6 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.458
Theoretical maximum density at 25°C (77°F): 153 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
2024TMSG-SP-0021 | 103.69 KB | 05/21/2024 | 2024-04-16-85-2 | Info |
Test was verified on 7/1/2024 ✔