Summary for Test 2024-05-14-15-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214135 DEA: 09213404 EFIS: 0900000030 |
---|---|
DIST-CO-RTE-PM | 09-INY-395-29.9/41.8 |
Award Date | 10/22/2021 |
Closeout Date | Not set |
Work Description | ROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT. |
Location Description | INYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE |
QA Service Level | 1 (Verified on 05/03/2019) |
Sample Information
Sample Taken Date | 05/14/2024 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2024 |
Sample type | Quality Assurance | A brief description of the sample | Hot Plant, PSU#3 |
The quantity of what the sample constitutes | 8 boxes HMA, 1 bag Cold Feed, 1 bag RAP | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jerid | Last name of sampler or witnessed by | Kupelian |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refining Co Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | CAO 125 |
Test Details
DIME Sample ID: 2024-05-14-15
DIME Test ID: 2024-05-14-15-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-05-17
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 05/16/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4,250.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6,288.1 g
Mass of HMA Sample prior to ignition: 2,037.2 g
Mass Loss: 101.7 g
Mass of aggregate remaining after ignition: 1,935.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.25 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.74 %
General comments (publicly viewable) (Max 1000 characters): 5/14/24 HMA
Ignition oven
RICE
Air Voids
Hamburg
Test was verified on 5/17/2024 ✔